Smoke temperature: 0~700 ℃
Smoke pressure: -30KPa~+KPa
Probe material: 316L
Display: 4-digit number display
Output: 4-20mA
Protection level: IP65
Power supply: 220V
Range: set within 0-25%
There are two forms of analyzers: split type and integrated type.
The analyzer is widely used in industries such as power, metallurgy, heating, building materials, electronics, and petrochemicals due to its simple structure, easy maintenance, fast response speed, and wide measurement range. It analyzes the oxygen content of flue gas in various industrial boilers and kilns, improves combustion efficiency, saves energy, and reduces environmental pollution.
Technical features
·Strong universality.
·Large screen blue background white text LCD display, full Chinese operation menu.
·Oxygen range can be freely set within 0-25%
·Repeatability: (excluding cases where the reference gas is naturally convective)
± 0.5% (not greater than 0-25vol% O2 range)
± 1% (not greater than 0-25vol% O2 and within the range of 0-100vol% O2)
·Linearity: (excluding standard gas error)
(Except when the reference gas is a natural convection gas)
(Using a gas with a known oxygen concentration (within the measurement range) as the zero point gas and range calibration gas)
±1%; Not exceeding the range of 0-25vol% O2.
·Environmental temperature: -20~+55 ℃ (the temperature on the surface of the box can be -5~+70 ℃)
·Humidity range: 0~95% RH (no condensation)
·The temperature is controlled by PID, with constant temperature points of 700 ℃ and 750 ℃ (can be selected on site).
·Oxygen level upper and lower limit alarm indicators and temperature upper and lower limit alarm indicators can be set.
·One key correction of background potential.
·Standard gas can be used for online calibration.
·The 4-20mA standard current output is optically isolated from the main circuit and can be directly transmitted into the DCS system.
·Multiple fault information prompts.